Описание

Controller, Not Subject to Export Control, with Camera Function
Model LT-9501H
Measuring unit compatibility Measuring units are interchangeable without factory recalibration.
Display Minimumdisplayable unit 0.1 µm*1, 1 µm2, 0.01 °
Display range ±9,999.99 µm, ±999,999 µm2, 9,999.99 °
Microscope function Available
Display cycle 10 times/sec.*2
Terminal block Analogue output ±10 V x 2 outputs, output impedance: 100 ?
Timing input Non-voltage input
Reset input
Auto-zero input
Monitor dedicated power supply 24 VDC*3
Control I/O Judgment mode 3-step limits output For OUT1 and OUT2, and NPN open collector output*4
Binary mode Binary output Measured data output (21 bits), OUT1/OUT2/PROFILE selectable NPN open collector output*4
Strobe output NPN open collector output*4
Binary selector output
Binary selection input Non-voltage input*4
Stability output NPN open collector output
Laser remote input Non-voltage input
Program switching input Non-voltage input x 3 inputs
RS-232C interface Measured data output and control I/O (Selectable up to baud rate 115200 bps.)
Video output NTSC compliant (PIN connector)
Main functions Displacement mode Distance measurement, Transparent objectthickness measurement, Angle measurement,Relative angle measurement, Surface selection,Dark-out, Mask, Trend graph display, and Scanwidth/interval change*5
Profile mode Area selection (Average, Maximum, Minimum, Maximum-to-minimum, Area) Area calculation, Scan width/interval change, Dark-out, Smoothing, Averaging, and Profile data output*6
Common Light intensity accumulation, Microscope (LT-9501H, LT-9501HSO (5654) only), Tolerance judgement, 8-program registration, Calibration, Averaging, Hold modes, Auto-zero, and interface language selection
Rating Power voltage 100 to 240 VAC ±10 %, 50/60 Hz
Power consumption 110VA or less
Environmental resistance Pollution degree 2
Overvoltage category II
Ambient temperature 0 to +35 °C
Relative humidity 35 to 85 % RH (No condensation)
Weight Approx. 2.4 kg
*1 Display changes every ±0.3 µm. *2 Varies depending on the setting *3 Dedicated power supply for the monitor specified by KEYENCE. *4 Select either the Limits mode or the Binary mode. *5 Select either the Distance mode or the Profile mode. (Only distance mode is available with the LT-9501HSO (5654) and LT-9001HSO (5655).)The rating of the NPN open-collector output is 30 mA (30 V or lower) maximum, and residual voltage is 0.5 V.The rating of the Non-voltage input is ON voltage 1 V or lower, and OFF current 0.6 mA or lower. *6 Select either the Distance mode or the Profile mode. (Only distance mode is available with the LT-9501HSO (5654) and LT-9001HSO (5655).) The rating of the NPN open-collector output is 30 mA (30 V or lower) maximum, and residual voltage is 0.5 V. The rating of the Non-voltage input is ON voltage 1 V or lower, and OFF current 0.6 mA or lower.
''